800G QSFPDD Direct Attach Cable (DAC)

QSFP-DD112 (quad small form-factor pluggable double density) doubles the density of QSFP interconnects with an eight-lane electrical interface capable of 56 Gbps NRZ or112 Gbps PAM-4 to achieve 400 or 800 Gbps aggregate per port. The QSFP-DD112 port folio’s backwards compatibility allows existing QSFP112 modules to be plugged into QSFP-DD112ports, provide low loss, less skew and better NEXT, providing superior thermal and signal integrity performance.

General Description

QSFP-DD112 (quad small form-factor pluggable double density) doubles the density of QSFP interconnects with an eight-lane electrical interface capable of 56 Gbps NRZ or112 Gbps PAM-4 to achieve 400 or 800 Gbps aggregate per port. The QSFP-DD112 port folio’s backwards compatibility allows existing QSFP112 modules to be plugged into QSFP-DD112ports, provide low loss, less skew and better NEXT, providing superior thermal and signal integrity performance.

 

 

 

Features

   Operating case temperature:0~70C

  Compliant with IEEE802.3CK

Compliant with QSFPDD MSA

  RoHS compliant

 

Applications

  Servers

  Switches

  Routers

  Datacenters

  High performance computing

800qsfp1.jpg

Wiring Diagram

800qsfp2.jpg

Environment Performance

Item

Value

Testing Condition

Operating Temp. Range

0°C to+70°C

Cable operating temperature ange.

Storage Temp.Range (in   packed condition)

-40°C to+80°C

Cable storage   temperature range in packed condition.

Thermal Cycling Non-Powered]

No evidence of physical damage

EIA-364-32D,Method A, -25   to 90C,100cycles,15min.   dwells

Salt Spraying

48hours salt spraying after shell corrosive area lessthan5.

EIA-364-26

Mixed Flowing Gas

Pass electrical tests   per3.1after stressing. (For connector only)

EIA-364-35 ClassII,14 days.

Temp.Life

 

 

No evidence of physical damage

EIA-364-17C w/RH, Damp heat 90    at

85%RH for 500hours then return to ambient

Cable Cold Bend

4H,No evidence of physical damage

Condition: -20±2,mandrel diameter is 6 times the cable diameter.

 

Mechanical and Physical Characteristics

Item

Requirement

Testing Condition

Vibration

Pass electrical tests

per 3.1 after stressing.

Clamp & vibrateperEIA-364-28E,

TC-VII, test condition letter –D,15 minutes  in X, Y & Zaxis.

 

Cable Flex

 

 

No evidence of physical damage

Flex cable180° for 20 cycles(±90° from nominal position) at 12 cycles per minute with a1.0kg   load applied to the cable

jacket. Flex in the boot area   90ºineachdirection from   vertical. Per EIA-364-41C

Cable Plug Retention in Cage

125NMin.

No evidence of physical damage

No functional damage to module, connector, or   cage with latching mechanism activated.

Per OSFP _Specification_Rev5_0 5.0

 

Cable Retention in Plug

90NMin.

No evidence of physical damage

Cable plug is fix-tured with the bulk cable hanging   vertically A 90N axial load is applied (gradually) to the cable   jacket and held for1minute.PerEIA-364-38B

Mechanical Shock

Pass electrical tests

Per 3.1 after stressing.

Clamp and shock   perEIA-364-27B, TC-G,3 times in 6   directions,100g,6ms.

 

Cable Plug Insertion

 

 

40NMax.(55N)

Per OSFP _Specification_Rev5_0 5.0Module to be inserted into connector and cage with latch   mechanism engaged. (55N if the cage has riding heat sink)

 

Cable plug Extraction

 

 

30NMax.(45N)

Per OSFP   _Specification_Rev5_0 5.0

Module to be removed from connector and cage with latching mechanism disengaged.(45N if the cage has riding heat sink)

 

Durability

 

 

50 cycles, No evidence of physical damage

Per OSFP   _Specification_Rev5_0 5.0,

Number of cycles for an individual module,to be tested with cage, connector, and

module; latches maybe locked out during testing

 

 

 

Package Diagram

Both ends of the connector use protective sleeve protection, each into a separate anti-static bag.

 

800qsfp3.jpg

Ordering Information

 

Part Number

Data Rate

Length

Wire Gauge

Temp. Range

Note


800G

0.5M

30AWG

0-70°C



800G

1M

28AWG

0-70°C



800G

1.5M

28AWG

0-70°C


 



-->

Product recommendation